Factory Floor

INDUSTRIAL FOAM PUMPER REFURBISHMENT

Custom Remanufactured for Sunoco Logistics - Energy Transfer

Bulletpoint Specs

Truck Type: Industrial Pumper Refurbishment

Chassis Model

REMANUFACTURE OF CNF FOAM PUMPER – INDCLUDING NEW FIRE PUMP & FLOW BASED FOAM SYSTEM

SPARTAN GLADIATOR CHASSIS, 1995 MODEL GA20E-2142  

  • Replace Original Chassis Radiator Core, Top & Bottom Hoses, Heater Hoses, and all Hose Clamps
  • Replace Chassis Air Conditioner, Including: Evaporator, Condenser, and Engine-Driven Compressor
  • Replace all Emergency Lighting Fixtures with New NFPA-Approved High Intensity LED Light Fixtures
  • Replace all DOT Non-Emergency Lighting Fixtures
  • Replace Cab Roof Mounted Lightbar with New LED Light Bar, with NFPA-Approved Patterns and Exemption
  • Replace Front Bumper Extension Gravel Shield, with New Polished Aluminum Treadplate or Stainless Steel
  • Replace Original PTO, with New Chelsea Hot-Shift PTO, Compatible with New Hydraulic Foam Pump Drive
  • Replace Original Exterior Cab Handrails with New Extruded Knurled Aluminum Non-Slip Handrails
  • Provide Four (4) New Telescoping LED High Intensity Scene Lights, One Each Side-Rear of Cab & Rear of Body
  • Provide Four (4) New LED Under-Cab Ground Illuminating Lights, At Each Door Step Area
  • Provide New Reflective Graphics, Sides and Front of Cab

“NEW” INDUSTRIAL WATEROUS-3500 / FOAM PRO ACCUMAX-300 TOP-CONTROLLED PUMP MODULE

  • Following Replaced the Original Hale 8F-3000 Fire Pump & National Foam Servo Command-300 BP Foam System:
  • Brushed Stainless Steel “fabricated bolted assembly” Full Width Top-Mount Pump Module
  • Polished Treadplate Aluminum Runningboards, Operator’s Walkway & Intermediate Steps
  • Waterous CRU-2, 3500-gpm Industrial Fire Pump, with TC-21 Extra Heavy Duty Chain-Drive Transmission
  • Waterous Pneumatic Pump Shift, with Cab Dashboard Remote Shift Control Console
  • Akron Hose Line Discharge Valves and Akron LDH Discharge Valves
  • Waterous Pump Overheat Protection, Pump Cooling System
  • Two (2) each, Waterous VPOS 12-Volt Electric Primers
  • FRC Engine Electronic Pressure Governor with Digital Engine Instrumentation
  • Fire Pump 6” ASA Flanged Outlet, 10” Victaulic Suction Inlet
  • Contour-Flow 8” x 6” stainless steel discharge waterways, with two (2) Zinc Anodes
  • Discharge 8” Riser Manifold, Gated for Overhead 6000-GPM Monitor
  • Contour-Flow 2-10” x 4-8” stainless steel suction manifolds w/2-Zinc Anodes, Inlets Reduced to 6” NST
  • Dual (2) Bronze Pre-Set Suction Manifold Intake Relief Valves
  • Foam Pro AccuMax- 300-gpm Flow-Based Electronically Controlled Direct Discharge Injection Foam System
  • 10-Operator’s Panel Mounted Digital Line Control Consoles, 1-per Foam Capable Discharge
  • Analog NoShok Liquid-Filled 4” Gauges, 2 each, 1-Master Intake & 1-“Duplex” Foam/Water Pressure
  • Analog NoShok Liquid-Filled 2.5” Gauges, 10 each, 1-Per Gated Discharge
  • 4-Pump suctions, 6” Driver (2), 6” Officer (2), 6” NST Male with Strainers and Long Handled NST Caps
  • 2-Gated Pump Suctions, 2-1/2”, 1-Driver and 1-Officer Sides, with Strainers and NST Swivel Female Inlets
  • 10-Foam capable gated discharges, Waterous & Akron electric valves with position indicators:
    • 2-2” Cartridge Style Speed-Lays, 1-1/2” NST
    • 1-2-1/2” Overhead Cross-Lay, 2-1/2” NST
    • 1-2-1/2” Outlet, 2-1/2” NST: Driver Side
    • 1-2-1/2” Outlet, 2-1/2” NST: Officer Side
    • 4-6” Outlets, 6” NST: Driver (1), Officer (1), rear (2)
    • 1-6” Overhead-Pump Module Monitor Discharge
    • 1-Foam Pump Concentrate Gated Inlet, Driver Side, 2-1/2” NST
    • 1-Foam Pump Concentrate Gated Off-Board Outlet, Driver Side, 1-1/2” NST

 “NEW” FOAM CONCENTRATE TANK

  • 500-gallon Poly Foam tank with NFPA foam expansion Fill Tower
  • Stainless Steel Neoprene Rubber Lined Foam/Water Tank Cradle
  • IC Operator’s Panel Foam Level Indicator
  • 3” Foam tank-to-Foam Pump valve & stainless piping
  • 2” Foam Pump-to-Foam Tank Fill Discharge

“NEW” REPLACEMENT CHASSIS AND APPARATUS BODY VISUAL WARNING, COMPARTMENT & SCENE LIGHTING

  • Refurbish Original Apparatus Body Power Distribution Center
  • New LED Arrow Front Chassis Turn Light Fixtures
  • New LED Non-Emergency Light Fixtures and Wiring for Same
    • Shielded Pump Panel Runningboard, Intermediate Step, Operator’s Platform Lighting
    • Shielded Rear Body Tailboard and Steps Lighting
    • DOT 7-each Marker Lights, Side, Mid-Turn, and Rear
    • License Plate Lighting and Reflectors
    • Stop – Tail – Turn – Backup Lighting, 6-each
    • 11 each, Compartment Interior Strip Lights
    • Perimeter Under-Body Ground Lighting
  • LED Emergency Light Bars and Fixtures
    • Whelen Freedom Cab Roof Lightbar Zone A Upper
    • Two (2) Front Grille Warning Zone A Lower
    • Two (2) Side Bumper Warning Zone B & D Lower
    • Four (4) Side Body Wheelwell Warning Zone B & D Lower
    • Two (2) Top Rear Body Beacons Zone C Upper
    • Two (2) Lower Rear Body Warning Zone C Lower
  • 14-LED light strips, 2-per compartment
  • LED Scene Lighting
    • Two (2) Tele-Scoping at Walkway Platform
    • Two (2) Tele-Scoping on Rear Body Corners

APPARATUS LINE VOLTAGE ACCESSORIES

  • 120-Volt Shoreline
  • 120-Volt Gast Onboard Automatic Air Compressor
  • 120-Volt Powermax Automatic Onboard Battery Charger

LETTERING, STRIPING, AND GRAPHICS

  • Reflective Body and Cab Stripes, Full Length of Apparatus, Driver & Officer Sides